Case Size |
2.5 inches (63 mm)
6 inches (150 mm)
|
Case Material |
AISI 304 Stainless Steel solid case
6 inch models: Case and socket are welded together
|
Ring |
AISI 304 Polished Stainless Steel Bayonet Bezel Ring
|
Window |
Safety Glass standard
|
Socket |
2.5 inch: AISI 316 Stainless Steel
6 inch: Removable Stainless Steel Restrictor
|
Connection |
2.5 inch: 1/4 inch NPT
6 inch: 1/2 inch NPT. 1/4 inch NPT optional (special order).
|
Accuracy |
± 1% on ranges below 10,000 PSI
±1.6% on ranges 15,000 PSI and above
|
Bourdon Tube |
AISI 316 Stainless Steel.
2.5 inch: Ranges less than 600 PSI utilize a C-tube configuration. All other ranges utilize a spiral tube.
6 inch: Ranges less than 1000 PSI utilize a C-tube configuration. All other ranges utilize a spiral tube.
|
Movement |
304 Stainless Steel
|
Pointer |
2.5 inch: Balanced black aluminum
6 inch: Balanced black aluminum, micrometer adjustable
|
Dial |
White aluminum with black markings in accordance with ASME B40.1 -2005
|
Scales Available |
PSI
Bar
kg/cm2
kPa
Dual Scale
|
Ambient Temperature Limits |
Dry: -40° to 185°F (-40° to 85°C)
Glycerin Filled: 60° to 150°F (15° to 65°C)
Silicone Filled: -50° to 150°F (-45° to 65°C)
|
Process Temperature Limits |
-40° to 176°F (-40° to 80°C). 100°C Max.
|
Overpressure Limits |
30% for ranges up to 870 PSI (60 Bar)
25% for ranges from 870 to 1,400 PSI (100 Bar)
15% for ranges above 1,400 PSI (100 Bar)
Overpressure in excess of these values may affect calibration
6 inch (Dry models only): Overpressure in excess of these values may affect calibration, but will not damage the movement due to the mechanical stops.
|
Available PSI Ranges |
10 PSI
15 PSI
30 PSI
60 PSI
100 PSI
160 PSI
200 PSI
300 PSI
400 PSI
500 PSI
600 PSI
800 PSI
1,000 PSI
1,500 PSI
2,000 PSI
2,500 PSI
3,000 PSI
4,000 PSI
5,000 PSI
6,000 PSI
10,000 PSI
15,000 PSI
20,000 PSI
6 inch only:
25,000 PSI
30,000 PSI
|
Available Vacuum Ranges |
-30 inches of HG to 0 PSI
|
Available Compound Ranges |
0 PSI (-30 inches of HG) to 15 PSI
0 PSI (-30 inches of HG) to 30 PSI
0 PSI (-30 inches of HG) to 60 PSI
0 PSI (-30 inches of HG) to 100 PSI
0 PSI (-30 inches of HG) to 150 PSI
0 PSI (-30 inches of HG) to 200 PSI
0 PSI (-30 inches of HG) to 300 PSI
|
Available Mounting Styles |
Stem Mount, Lower Connected (standard)
Stem Mount, Back Connected (2.5 inch: special order)
6 inch only:
Flush Mount, Back Connected, U Clamp (special order)
Flush Mount, Back Connected, Front Flange (special order)
Surface Mount, Lower Connected, Rear Flange (special order)
|
Fill |
Dry
Wet (Glycerin fill standard)
2.5 inch only: Optional Silicone (special order only)
|
Ingress Protection |
Dry: IP54
Wet: IP64
|
Warranty |
Dry: 1 Year Warranty for defects in materials or workmanship
Wet: 2 Year Warranty for defects in materials or workmanship
|
Options |
6 inch: Autoclave fitting available, must specify male or female connector at time of order. Blow out disc available for dry or glycerin filled gauges only; must be specified at time of order.
|
NIST Available? |
Yes
|
Note |
For Non-Stock items, a minimum order quantity may apply.
|